UTP Unschützte Katze 6 Patch Panel
video
UTP Unschützte Katze 6 Patch Panel

UTP Unschützte Katze 6 Patch Panel

Patch Panel UTP Cat 6 meets all TIA/EIA-568-C.2 Category 6 and ISO 11801 2nd Edition Class E channel requirements at swept frequencies up to 250 MHz, Meets ANSI/TIA-568-C.2 and ISO 11801 Category 6 component requirements at swept frequencies up to 250 MHz entspricht ANSI/TIA -1096 a (früher ...

Beschreibung

This Cat 6 UTP Patch Panel meets all TIA/EIA-568-C.2 Category 6 and ISO 11801 2nd Edition Class E channel requirements at swept frequencies up to 250 MHz, Meets ANSI/TIA-568-C.2 and ISO11801 Category 6 component requirements at swept frequencies up to 250 MHz entspricht ANSI/TIA -1096 a (ehemals FCC Teil 68); Erfüllt IEC 60603-7, unterstützt IEEE 802 . 3AF/802.3 AT und vorgeschlagen 802.3BT Typ 3 und Typ 4 POE -Anwendungen, UL1863 Genehmigt und ROHS -Beschwerde.


Spezifikation

Produktname

Patch Panel UTP Cat 6

Produkttyp

Patch Panel Kit

Kündigungsstil

Niederschlagen

Patch -Panelstil

Wohnung

Leistungsniveau

Kategorie 6

Material

CRS

Verdrahtungsprogramm

T568A/T568B

Anzahl der Ports

24

Modultyp

RJ45

Anzahl der Rack -Einheiten

1

Gesamtbreite (in .)

19

Gesamtbreite (MM)

482.6

Farbe

Schwarz


Merkmale:

1. Für den Keystone-Jack-Teil des Patch-Panels wird die Phosphorbronze zuerst mit Nickel plattiert und dann mit einer 24-Karg-Golddicke von bis zu 50U〃 plattiert, und das Verstopfungsleben überschreitet 800 mal .}}} astieren. Übertragung .

Oder UL94V -0.


3. Cat6-Patch-Patch-Panel ist ein Gerät, das zum Beenden und Verwalten von Endbenutzer- oder Rumpfkabeln verwendet wird, und ermöglicht ihre flexible Verbindung und Bereitstellung . Es ist eine entscheidende Komponente im Management-Untersystem und dient als Hub für die Querverbindungen. In Racks oder an Wänden . Mit der Installation von Zubehör können Patch-Panels die Anforderungen von UTP, STP, Koaxialkabeln, Faseroptik und Audio-/Videoanwendungen erfüllen. und Zwischenverteilungsrahmen (IDFs) basierend auf ihrer Verwendung und ihrem Standort .

Oder wird für Testanordnungen oder Terminalblöcke . für Rumpflinien oder spezielle Linien verwendet, die keinen Schutz erfordern In den frühen Tagen waren MDFs groß, wobei jeder vertikale Abschnitt 303 Zeilen . Schutzanordnungen mit 20 oder 21- Linien-Kohlenstoff-Blitz-Arrestern mit thermischen Spulen verwendet haben, um den Strom zu begrenzen. new generation of MDFs, designed to work with computer-controlled exchanges, have significantly reduced size and weight, with each vertical section able to accommodate 1,000 lines. Protection arrangements consist of blocks with 100 lines, using metal discharge tubes to prevent high voltage and overcurrent. Test blocks consist of blocks with 128 lines, allowing for easy separation of contacts to facilitate line testing. Each wire connected to the terminal has its own independent cable tray for easy installation and maintenance. The connection in the protection arrangement is made through card connection, eliminating the need to strip the insulation layer of the wire. The connection in the test arrangement is made through winding. Both connection methods are characterized by their simplicity, reliability, speed, und mangelnde Verschmutzung . Abhängig von der Anwendung sind neue Arten von Patch-Panels in Wandmontage, bodengesteuertem, einseitigen und doppelseitigen Konfigurationen erhältlich .

5. mdfs dienen hauptsächlich folgende Funktionen: 1) Schutz: Sie bieten Schutz gegen Hochspannung und übermäßigen Strom für Benutzerlinien . 2) Verteilung: Sie ermöglichen jedem Benutzer, eine Zahl innerhalb der Räumlichkeiten auszuwählen, und Rumpflinien zwischen Differenzangehörigen können auch mit den Anforderungen der Angaben zu den Anforderungen der Angaben zu den Anforderungen der Angaben zu den Anforderungen der Angaben zu den Anforderungen der Anzahl der Angaben .}}}}}}}}}} sie können. Zeilen .

6. idf, auch als Zwischenstufe bezeichnet, ist ein Patch-Panel, das die interne Linienverteilung innerhalb der Telefonaustausch . IDFs verbindet, kann basierend auf ihrem Standort in zwei Typen eingeteilt werden: dem Intermediate-Verteilungsrahmen zwischen dem Hauptverteilungsrahmen und dem Intra-Room-Rahmen .}}}

IDFs sind auch mit vertikalen und horizontalen Abschnitten . strukturiert. Der vertikale Abschnitt wird für ausgehende Linien von Geräten verwendet, während der horizontale Abschnitt für eingehende Linien zu Geräten verwendet wird Löten oder

STP Cat6 Patch Panel

1U 24 ports Cat6 Patch Panel


Klicken und durchsuchen Sie mehrKatze 6 Patch Panels


Um die Produktionskapazität und die internationale Zertifizierung unserer Fabrik zu sehen . klicken Sie aufÜber uns


Beliebte label: UTP Unschützte Katze 6 Patch -Panel, Lieferanten, Hersteller, Fabrik, Großhandel, Preis, Preisträger, Angebot, Masse, billig, Terminalbox, Ethernet -Netzwerk -Patch -Panel .

Das könnte dir auch gefallen

Einkaufstüten